|
Control Cables:Used in interconnection of process
control, communication and panel control systems. Electrical Wiring Cables: Used for electric power, lighting
& internal wiring. |
Used in connection of power
supply to residential, commercial
& industrial units. |
Used in data acquisition
systems, computer networking,
PA systems, digital control /
measuring & communication
systems. Specially designed to
transmit signals without any
external interference. |
Used to extend thermocouple
circuits from the sensor to
reference unit. |
|
PVC / XLPE insulated cables
conforming to IS:1554-I / IS:7098-I,
BS:6346, IEC:60502, BS:5467,
BS:7846, IEC:60227, BS:6004,
BS:6500, IS:694 and Customer
specific requirements.
Control Cables:
Generally with conductor sizes
1.5 /2.5 / 4.0 sq.mm.
Electrical Wiring Cables:
Single Core cables upto 630
sq.mm.
Multi Core cables upto 50 sq.mm. |
PVC / XLPE insulated cables
conforming to IS:1554-I / IS:7098-I,
BS:6346,IEC:60502, BS:5467,
BS:7846 and Customer specific
requirements.
Single Core cables upto 1000
sq.mm.
Multi Core cables upto 400 sq.mm. |
Generally manufactured with
conductor sizes 0.5 / 0.75 / 1.0 /
1.5 sq.mm.
Conforming to BS:5308-I & II,
IEC-189, VDE 0815,
IEC:60227, BS:7846 and
Customer specific
requirements. |
Generally manufactured with
conductor sizes 16, 18 & 20 AWG.
Conforming to IS:8784, BS:4937,
IEC-584, ANSI:MC:96.1, DIN,
JIS and Customer specific
requirements. |
|
Conductor:
Solid / stranded / flexible copper,
circular / shaped, copper /
aluminium.
Insulation:
PVC – GP / HR; XLPE, LSZH, EPR
Inner Sheath:
PVC – GP / HR / FR / FRLS; LSZH
Armour (for Armoured Cables):
Galvanised steel wire / strip / tape /
double tape or aluminium wire.
Outer Sheath:
PVC – GP / HR / FR / FRLS; LSZH |
Conductor:
Solid / stranded, circular / shaped,
copper / aluminium.
Insulation:
PVC –GP / HR; XLPE, LSZH, EPR
Inner Sheath: PVC – GP / HR /
FR / FRLS; LSZH
Armour (for Armoured Cables):
Galvanised steel wire / strip / tape
or aluminium wire.
Outer Sheath:
PVC – GP / HR / FR / FRLS; LSZH |
Conductor: solid / stranded / flexible
copper (bare / tinned)
Insulation: PVC – GP / HR; PE, XLPE,
LSZH, EPR Shielding:
Individual & overall or overall
screen only by Al-mylar tape /
copper tape / copper wire braid
Inner Sheath:
PVC – GP / HR / FR / FRLS;PE, LSZH, EPR
Armour (for Armoured Cables):
Galvanised steel wire / strip / tape /
double tape / braid
Outer Sheath:
PVC – GP / HR / FR / FRLS; PE, LSZH, EPR |
Conductor:
Solid / stranded; Type: KX, VX, TX,
JX, EX, R or S (SX)
Insulation:
PVC – GP / HR; PE, XLPE, LSZH, EPR
Shielding:
Individual & overall or overall
screen only by Al-mylar tape /
copper tape / copper wire braid
Inner Sheath:
PVC – GP / HR / FR / FRLS; PE,
LSZH, EPR
Armour (for Armoured Cables):
Galvanised steel wire / strip / braid
Outer Sheath:
PVC – GP / HR / FR / FRLS; PE, LSZH, EPR |